ASTM C1399 PDF

This document describes the main differences between ASTM C and ASTM C when it comes to testing of flextural strength in fiber reinforced concrete. ASTM C determines the slow crack growth parameters of advanced fiber- reinforced concrete by using constant stress-rate flexural testing in which flexural . ASTM C Standard Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete. This test method covers the determination of.

Author: Zulukinos Tygogami
Country: Russian Federation
Language: English (Spanish)
Genre: Technology
Published (Last): 27 October 2011
Pages: 337
PDF File Size: 4.57 Mb
ePub File Size: 3.16 Mb
ISBN: 304-1-70591-879-9
Downloads: 31961
Price: Free* [*Free Regsitration Required]
Uploader: Kajizragore

A load rating of 10, lbf will generally be required.

ASTM C – 01 Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete

By means of our testing expertise and modular product design, we will help find the testing solution that is right for you. Combining values from the two systems may result in non-conformance with the standard.

It allows for comparative analysis among beams containing different fiber types, including materials, dimension and shape, and different fiber contents. The values stated in each system may not be exact equivalents; asfm, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Your Alert Profile lists the documents that will be monitored.

E Deflectometer Deflection Gauge. For tests of fiber-reinforced concrete containing relatively rigid or stiff fibers of length greater than 35 mm [1. This standard is not included in any packages. Give one of our application engineers a call today for help with creating the best budget and testing plan according to ASTM.

ASTM C1399 Residual Strength Fiber-Reinforced Concrete Test Equipment

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to atm. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  CONVERT ACTUATE ROI TO PDF

ast, The average residual strength is computed using specified beam deflections that are obtained from a beam that has been cracked in a standard manner. This standard does not purport to address all of the safety concerns, atm any, associated with its use. ASTM C determines the slow crack growth parameters of advanced fiber-reinforced concrete by using constant stress-rate flexural testing in which flexural strength is determined as a function of applied stress rate in a given environment at ambient temperature.

We have no amendments or corrections for this standard.

You may delete c13399 document from your Alert Profile at any time. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

Proceed to Checkout Continue Shopping. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. The test provides data needed to obtain that portion of the load—deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of post—cracking strength, as such strength is affected by the use of fiber—reinforcement.

As the voice of the U. Results can be used to optimize the proportions of fiber—reinforced concrete mixtures, to determine compliance with construction specifications, to evaluate fiber—reinforced concrete which has been in service, and as a tool for research and development of fiber—reinforced concrete See Note 2.

The values in parentheses are for information only. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  FUGA CON PAJARILLO ALDEMARO ROMERO PDF

Active view current version of standard. The test provides data needed to obtain that portion of the load — deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of post — cracking strength, as such strength is affected by the use of fiber — reinforcement.

Standards Subsctiption may be the perfect solution. Already Subscribed to this document. The results by this test method were on average 6.

ASTM C Residual Strength Fiber-Reinforced Concrete Test Equipment

Please first log in with xstm verified email before subscribing to alerts. If the document is revised or amended, you will be notified by email. Available from a 1 mm 0. Add to Alert PDF. Please first verify your email before subscribing to alerts. The test provides data needed to obtain that portion of the load-deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of post-cracking strength, as such strength is affected by the use of fiber-reinforcement.

ASTM C1399/C1399M – 10(2015)

Force range of aztm kN to kN 1, lbf tolbf Adjustable test space The most popular choice for static tension and compression tests These dual column testers are available in both tabletop and floor standing models. Subscription pricing is determined by: We are confident that we have what you are looking for. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.